What is roofing felt? It is a roll underlayment, traditionally an organic or fiberglass mat saturated with asphalt, that is laid over the roof deck before shingles or other roofing go on. Often called tar paper, it acts as a secondary layer that sheds water, protects the deck during construction, and helps the roof meet fire ratings.
Is roofing felt waterproof? No. It is water-resistant, which means it sheds water and slows moisture, but it is not designed to be a sealed, waterproof layer or a standalone roof. For true waterproofing at the eaves and valleys, roofs use self-adhering ice barrier membranes. Below, we explain how No. 15 and No. 30 felt differ, how felt compares with synthetic underlayment, and how long it can safely be left exposed.
In this article
- What is roofing felt?
- Is roofing felt waterproof?
- What roofing felt does on a roof
- No. 15 vs. No. 30 felt: ASTM D226 and D4869
- Roofing felt vs. synthetic underlayment
- How long can roofing felt be exposed?
- Felt, ice barrier, and self-adhering membranes
- What the building code says about underlayment
- Choosing the right underlayment
- Installation basics and safety
- Frequently Asked Questions
What is roofing felt?
Roofing felt is made by saturating a base mat with asphalt and forming it into rolls. Traditional “organic” felts use a mat made from cellulose fibers such as paper or wood fiber; some felts are reinforced with fiberglass. The finished product is a flexible black sheet, usually 36 inches wide, often printed with guide lines to help installers keep courses straight.
The name “tar paper” dates back to when roofing felts were made with coal tar. Today’s roofing felts are saturated with asphalt, but the nickname has stuck.
Felt is one type of underlayment, the layer between the roof deck and the finished roofing. The other main types are synthetic underlayments, made from woven or spun polymer fabrics, and self-adhering membranes made from rubberized asphalt.
Is roofing felt waterproof?
Roofing felt is water-resistant, not waterproof, and the difference matters.
- Water-resistant means a material sheds water and slows its passage. Water running down the slope flows over the felt and off the roof, and the felt keeps occasional wind-driven rain or melting snow from reaching the deck.
- Waterproof means water can’t get through even when it pools or is held against the surface. Felt doesn’t meet that standard. Water that sits on it, such as water backed up behind an ice dam, can eventually soak through laps and nail holes.
The Asphalt Roofing Manufacturers Association (ARMA) describes underlayment as water-resistant secondary protection against wind-driven rain and moisture. Even synthetic underlayments are labeled this way; GAF’s FeltBuster data sheet, for example, says plainly that the product is water-resistant but not waterproof.
One reason felt isn’t waterproof is that it doesn’t seal around fasteners. Every nail or staple that goes through it creates a small opening. Self-adhering membranes, by contrast, are made to seal around nails, which is why they are used where water is most likely to back up.
What roofing felt does on a roof
If felt isn’t waterproof, why use it at all? According to ARMA, underlayment does several jobs:
- Protects the deck before the roof is finished. It keeps rain off the sheathing between tear-off and shingle installation.
- Adds a second line of defense. If wind drives rain under a shingle or a shingle is damaged, the underlayment helps keep that water from reaching the deck.
- Helps meet fire ratings. Many roofing assemblies achieve their Class A, B, or C fire rating with underlayment included; shingles alone are not classified.
- Reduces “picture framing.” It helps prevent the outline of deck panels from showing through shingles.
- Separates shingles from the deck. It helps protect shingles from resins that may come out of wood decking.
Shingle manufacturers typically call for underlayment over wood decks, and building codes require it under most steep-slope roofing.
No. 15 vs. No. 30 felt: ASTM D226 and D4869
Felt comes in two traditional grades, No. 15 and No. 30. The names are older than the current standards and can be misleading, so it helps to know what the ASTM classifications mean.
ASTM D226: the traditional felt standard
ASTM D226 covers asphalt-saturated organic felt. It has two types:
- Type I, commonly called No. 15 felt
- Type II, commonly called No. 30 felt
The numbers once referred to weight in pounds per 100 square feet, one roofing square, but felts never actually weighed that much. According to IIBEC, the roofing consultants’ association, the minimum weight for saturated Type I felt is now 11.5 pounds per square, and Type II felt is about 26 pounds per square.
ASTM D4869: the steep-slope underlayment standard
ASTM D4869 was approved in 2002 specifically for steep-slope roofing underlayment. It has four types:
| ASTM D4869 type | Common name | Rough equivalent |
|---|---|---|
| Type I | #8 underlayment | Lighter than No. 15 |
| Type II | #13 underlayment | Similar to D226 Type I (No. 15) |
| Type III | #20 underlayment | Between No. 15 and No. 30 |
| Type IV | #26 underlayment | Similar to D226 Type II (No. 30) |
Unlike D226, D4869 includes a pass/fail liquid water transmission test and limits on how much the sheet can change size, which helps control wrinkling.
Watch the labels
IIBEC has warned that some products labeled “#30” or “No. 30” are actually lighter D4869 Type I or II felts weighing far less than a true D226 Type II. The only reliable way to know what you’re buying is to check the data sheet or wrapper for the exact ASTM standard and type, not just the number on the label.
No. 15 vs. No. 30 at a glance
| No. 15 (ASTM D226 Type I) | No. 30 (ASTM D226 Type II) | |
|---|---|---|
| Weight | About 11.5 lb per square minimum | About 26 lb per square |
| Thickness | Thinner | Roughly twice as thick |
| Typical roll | 36 in. x 144 ft, about 4 squares (TAMKO example) | 36 in. x 72 ft, about 2 squares (TAMKO example) |
| Tear and wrinkle resistance | Tears more easily and wrinkles when wet | Tougher and more durable underfoot |
| Common uses | Standard underlayment under shingles where allowed | Steeper or more demanding roofs, tile, slate, and longer construction exposure |
Roofing felt vs. synthetic underlayment
Synthetic underlayments are made from polypropylene or polyethylene fabrics, often with a coating for water resistance and slip resistance. They have largely replaced felt on many new roofs, though felt is still widely available and code-compliant.
| Feature | Asphalt felt | Synthetic underlayment |
|---|---|---|
| Typical roll coverage | About 2–4 squares per roll | Often 10 squares per roll (e.g., 48 in. x 250 ft) |
| Weight | Heavy, especially No. 30 | Much lighter; GAF lists about 23 lb for a 10-square roll of FeltBuster |
| Tear resistance | Lower; unreinforced No. 15 tears easily | High; resists tearing underfoot and in wind |
| Wrinkling | Can wrinkle when it gets wet | More dimensionally stable |
| UV/exposure tolerance | Dries out in sun; cover quickly | Product-specific, often 90 days to 6 months |
| Walking surface | Can be slippery, especially when wet or frosty | Many have textured, slip-resistant surfaces |
| Fastening | Per code and manufacturer | Usually requires cap nails or cap staples |
| Relative cost | Low | Often competitive with felt on a per-square basis, but varies |
| Standards | ASTM D226 or D4869 | ASTM D8257 and/or manufacturer evaluation reports |
A few cautions apply to synthetics. They must be fastened exactly as the manufacturer specifies; GAF, for example, requires plastic cap nails or cap staples on FeltBuster and warns never to use bare nails or staples. Products also vary widely in vapor permeability, which matters on some roof assemblies, so check the data sheet if your attic or cathedral ceiling depends on the roof drying out.
How long can roofing felt be exposed?
Felt is designed to be covered. Fine Homebuilding notes that asphalt felt dries out and loses water resistance in sunlight and isn’t meant to serve as an exterior membrane, so shingles should go on quickly. Felt that has been exposed to sun, rain, and wind for a long time can become brittle, wrinkled, or torn, and it should be inspected and replaced if needed before the roofing goes on.
Synthetic underlayments generally tolerate exposure much longer, but limits vary by product:
- GAF FeltBuster is rated to resist UV degradation for up to 90 days, and GAF notes this figure reflects UV testing only, not resistance to water, snow, or wind.
- Owens Corning Deck Defense can be left exposed for up to 6 months, with a special application required for extended exposure.
No underlayment, felt or synthetic, should be treated as a temporary roof. GAF’s FeltBuster data sheet specifically says not to use it as a temporary roof to protect property or possessions. If a roof is damaged and can’t be repaired right away, a properly secured tarp or an emergency repair is the right short-term solution.
Felt, ice barrier, and self-adhering membranes
In cold climates, ice dams are the situation where felt’s lack of waterproofing matters most. Water held behind a ridge of ice at the eave can back up under shingles and through ordinary underlayment.
That’s what ice barrier is for. The International Residential Code requires an ice barrier in areas with a history of ice forming along the eaves and causing water backup. It must consist of either:
- At least two layers of underlayment cemented together, or
- A self-adhering polymer-modified bitumen sheet, the peel-and-stick membrane most roofers use today.
The ice barrier must extend from the lowest edge of the roof to at least 24 inches inside the exterior wall line, and on roofs sloped 8:12 or steeper, at least 36 inches up the slope from the eave. Self-adhering membranes, which meet ASTM D1970, are also commonly used in valleys, around chimneys and skylights, and along other leak-prone areas. They seal around nails, which is the key difference from felt.
Typical layering on a cold-climate shingle roof is self-adhering ice barrier at the eaves and in valleys, then felt or synthetic underlayment over the rest of the deck, lapped over the ice barrier so water flows from one layer onto the next.
What the building code says about underlayment
Most U.S. residential codes are based on the International Residential Code. Key underlayment points include:
- Underlayment must meet one of the listed standards, which include ASTM D226, D4869, D6757, D1970, and D8257, and be labeled to show compliance.
- For asphalt shingles, D226 felt must be Type I or Type II.
- Asphalt shingles are allowed on slopes of 2:12 or steeper. On slopes from 2:12 up to 4:12, two layers of underlayment are required; at 4:12 or steeper, one layer is required.
- Distortions in the underlayment must not interfere with the shingles’ ability to seal, which is one reason wrinkled felt should be fixed before shingling.
- Ice barrier is required where ice damming is a known problem, as described above.
State and local codes can add their own amendments, and the shingle manufacturer’s instructions may call for specific underlayment. Check with your local building department and the manufacturer before choosing a product.
Choosing the right underlayment
There’s no single best underlayment for every roof. Consider these factors:
- The roofing manufacturer’s requirements. Shingle, metal, and tile manufacturers specify which underlayments are acceptable, and following those instructions matters for performance and warranty coverage.
- Roof slope. Low-slope shingle roofs between 2:12 and 4:12 need double underlayment or a fully adhered membrane.
- Climate. In snowy regions, ice barrier at the eaves and in valleys is essential, regardless of what goes on the rest of the roof.
- How long the deck will be exposed. If the roofing won’t go on for a while, a synthetic with a longer exposure rating is the safer choice.
- Roofing type. Heavier materials and some metal roofs have specific underlayment requirements, including temperature ratings for high-heat applications.
- Budget. Felt is inexpensive, but synthetics are often competitively priced, and the difference is small compared with the cost of the whole roof.
Installation basics and safety
If you’re planning a DIY project on a shed or small outbuilding, these basics apply. For a home, underlayment is part of a full roof installation and is best left to a professional crew.
- Start at the bottom. Lay the first course along the eave and work up so each course overlaps the one below, shingle-fashion, so water always flows onto the next layer, never behind it.
- Follow the printed lap lines and the manufacturer’s required side and end laps.
- Fasten per code and manufacturer instructions. Synthetics usually require cap nails or cap staples.
- Keep it flat. Wrinkles and buckles can telegraph through shingles and interfere with sealing.
- Cover it promptly. Don’t leave felt exposed longer than necessary.
- Install ice barrier first at eaves and valleys where required.
Safety first
Felt can be slippery, especially when wet, dusty, or frosty, and TAMKO’s product data warns that moisture, frost, and debris reduce traction. Use proper fall protection, wear soft-soled shoes, never work on a wet or icy roof, and check whether your project needs a permit. Asphalt products also carry manufacturer health warnings about dust and fumes during cutting, demolition, or heating, so read the safety data before you start. For more on planning a small roofing project, see our DIY roofing guide, and if you’re also shingling, our guide on how to install roofing shingles covers the next steps.
Frequently Asked Questions
Is roofing felt waterproof?
No. Roofing felt is water-resistant, not waterproof. It sheds water and protects the deck from wind-driven rain and short-term exposure, but it isn’t meant to be the roof covering and it doesn’t seal around nails the way a self-adhering ice barrier does.
What is the difference between 15 lb and 30 lb felt?
No. 15 felt (ASTM D226 Type I) is the thinner, lighter grade, and No. 30 felt (Type II) is roughly twice as heavy and thick, so it resists tearing and wrinkling better. Older names suggested 15 and 30 pounds per square, but actual weights are lower.
How long can roofing felt be left exposed?
Felt should be covered with the finished roofing as soon as practical, because sun and weather dry it out and reduce its water resistance. Follow the manufacturer’s instructions for the product you’re using; synthetic underlayments generally list longer exposure limits, often 90 days to 6 months depending on the product.
Is synthetic underlayment better than felt?
Synthetic underlayment is lighter, stronger, more tear resistant, and better at tolerating exposure, which is why it is now widely used. Felt is still code-compliant and inexpensive, and the best choice is whatever the shingle manufacturer and local code allow for your roof.
Can roofing felt be used as a temporary roof?
Not for long. Felt is not designed to be an exposed roof covering, and even synthetic underlayments such as GAF FeltBuster specifically warn against using them as a temporary roof to protect property. A properly secured tarp or emergency repair is the better short-term fix.
Is tar paper the same as roofing felt?
Yes, in everyday use “tar paper” means asphalt-saturated roofing felt. Modern felts are saturated with asphalt rather than coal tar, but the old name stuck.
Do I still need ice barrier if I use felt?
In cold climates, usually yes. The International Residential Code requires an ice barrier at the eaves where ice damming is a known problem, either two layers of underlayment cemented together or a self-adhering polymer-modified bitumen sheet, extending at least 24 inches inside the exterior wall.
Roofing felt is a water-resistant underlayment that protects the deck and backs up your shingles, but it isn’t waterproof and it isn’t meant to stay exposed. Choose the grade or synthetic alternative your roofing manufacturer and local code call for, use ice barrier where ice dams are a risk, and get it covered quickly. If you’d rather have a professional handle the job, see our roof installation page.